Wafergard® III NF-75 In-Line Gas Filters

Wafergard® III NF-75 In-Line Gas Filters

Superior particulate filtration for ultrapure gas system filtration  


● Cleanest, most efficient all-metal filters available
● Patented nickel filter membrane offers superior corrosion resistance and excellent compatibility with inert and reactive gases. (Not recommended for use with CO, O3 and low-level hydride dopant gases.)
● Ideal for high-temperature and dynamic-pressure applications
● Typically used for flows up to 75 SLPM


檔案下載:



規格說明:


Materials:
Filter element: Patented, sintered nickel membrane filter.
Housing: Electropolished F20 stainless steel housing
Surface finish interior: <=5 μin Ra
Helium leak rating: Qualified 2`10-10 atm-cc/sec. Tested 1`10-9 atm-cc/sec.

 
Downstream cleanliness:
Particles1: Less than 0.03 particles/Liter (<1 particle/ft3) greater than 0.01 μm
Volatiles2: Volatile outgassing of H2O, O2 and THC is below detectable limits (by RGA and FID at room temperature)

 
Particle retention:
Greater than 99.9999999% (9 LRV) removal of all particles at maximum rated flow (referenced at the most penetrating particle size)
 
Removal rating:
>=0.003 μm
 
Operating conditions:
Maximum inlet pressure: 70 bar (1000 PSI) at 100°C
Maximum forward/reverse differential pressure: 10 bar (150 PSID)
Maximum operating temperature: Inert gases 400°C at 35 bar (500 PSI); Corrosive and reactive gases: 50°C at 70 bar (1000 PSI)

 
Warranty:
5 year
 
Notes:
1) Particle cleanliness qualified following SEMASPEC Test Method for Particle Shedding (#93021511A-STD)
2) Volatile cleanliness qualified following SEMASPEC Test Methods for: THC Contribution (#90120396B-STD), Moisture Contribution (#90120397B-STD), Oxygen Contribution (#90120398B-STD)