訪客人數
現在位置:首頁產品介紹氣體過濾器SUS
Wafergard® III NF-750 In-Line Gas Filters

Wafergard® III NF-750 In-Line Gas Filters

Superior particulate filtration for high-purity gas system filtration


● Cleanest, most efficient all-metal filters available
● Patented nickel filter membrane offers superior corrosion resistance and excellent compatibility with inert and reactive gases. (Not recommended for use with CO, O3 and low-level hydride dopant gases.)
● Ideal for high-temperature and dynamic-pressure applications
● Typically used for flows up to 750 SLPM


檔案下載:



規格說明:


Materials:
Filter element: Patented, sintered nickel membrane filter.
Housing: Electropolished VAR 316L stainless steel housing
Surface finish interior: <=5 μin Ra
Helium leak rating: Qualified 2`10-10 atm-cc/sec. Tested 1`10-9 atm-cc/sec.
Total flow area: 140.0 cm2

 
Downstream cleanliness:
Particles(1): Less than 0.03 particles/Liter (<1 particle/ft3) greater than 0.01 μm at 300 SLPM
Volatiles: Volatile outgassing of H2O, O2 and THC is below detectable limits (by RGA and FID at room temperature)

 
Particle retention:
Greater than 99.9999999% (9 LRV) removal of all particles at 300 SLPM, greater than 00.0000% (6 LRV) removal of all particles at 750 SLPM (referenced at the most penetrating particle size)
 
Removal rating:
>=0.003 μm
 
Operating conditions:
Maximum flow rate: 750 SLPM
Maximum inlet pressure: 52 bar (750 PSI) at 100°C
Maximum forward/reverse differential pressure: 7 bar (100 PSID)
Maximum operating temperature: Inert gases 400°C at 27.5 bar (400 PSI); Corrosive and reactive gases: 50°C at 52 bar (7500 PSI)

 
Warranty:
5 year
 
Note:
(1) Verified at 100 SLPM for 1/4” gasket seal fitting (compatible with VCR® fitting).