Visitor
Now position:HomePRODUCTSGas Purifiers
GateKeeper® Inert Gas Purifiers

GateKeeper® Inert Gas Purifiers

Cost-effective, environmentally friendly gas purification


Consistently delivers ultrapure gas
Designed for use with N2, He, Ne, Kr, Xe, Ar, halocarbons and light hydrocarbons. The purifiers remove O2, H2, CO, CO2 and H2O to sub-ppb (part-per-billion) levels; SO2 to sub-ppt (part-per-trillion) levels.
Guards against bulk gas purifier breakthrough, impurity spikes from liquid storage tanks, cylinder changeouts and unexpected contaminants in the process
Does not release hydrocarbons that may contaminate the process
Uses ambient temperature purification technology – no power or heat required
Low pressure drop across purifiers


Download:



Specifications:


Materials of construction: 316L stainless steel, electropolished 10 Ra
Model 45M: Cr-Mo steel, SA 372, Grade F, Class 70
Media: Nickel metallic/metal oxide
Gases purified: N2 , He, Ne, Kr, Ar, halocarbons, light hydrocarbons
Outlet purity: <1 ppb H2, CO and CO2; <100 ppt H2O, O2
Model 45M: <100 ppb for all contaminants
Outlet particle filtration: 0.003 μm
Models 45M and 200M: 20 μm
Maximum differential pressure: 1379 kPa (200 PSID)
Minimum operating pressure: 101 kPa (14.7 PSIA)
Maximum flow rates: See datasheet.
Leak rating: 1 × 10-9 atm cc/sec.
Model 45M: 1 x 10-3 atm-cc/sec
Maximum inlet challenge of contaminant to maintain product efficiency: 10 ppm (part-per million)
Lifetime: One year at nominal flow rate with 1 ppm inlet challenge of moisture
Maximum operating temperature: 65°C (149°F)