GateKeeper® Inert Gas Purifiers
Cost-effective, environmentally friendly gas purification
● Consistently delivers ultrapure gas
● Designed for use with N2, He, Ne, Kr, Xe, Ar, halocarbons and light hydrocarbons. The purifiers remove O2, H2, CO, CO2 and H2O to sub-ppb (part-per-billion) levels; SO2 to sub-ppt (part-per-trillion) levels.
● Guards against bulk gas purifier breakthrough, impurity spikes from liquid storage tanks, cylinder changeouts and unexpected contaminants in the process
● Does not release hydrocarbons that may contaminate the process
● Uses ambient temperature purification technology – no power or heat required
● Low pressure drop across purifiers
Download:
Specifications:
Cost-effective, environmentally friendly gas purification
● Consistently delivers ultrapure gas
● Designed for use with N2, He, Ne, Kr, Xe, Ar, halocarbons and light hydrocarbons. The purifiers remove O2, H2, CO, CO2 and H2O to sub-ppb (part-per-billion) levels; SO2 to sub-ppt (part-per-trillion) levels.
● Guards against bulk gas purifier breakthrough, impurity spikes from liquid storage tanks, cylinder changeouts and unexpected contaminants in the process
● Does not release hydrocarbons that may contaminate the process
● Uses ambient temperature purification technology – no power or heat required
● Low pressure drop across purifiers
Download:
Specifications:
Materials of construction: |
316L stainless steel, electropolished 10 Ra Model 45M: Cr-Mo steel, SA 372, Grade F, Class 70 |
Media: | Nickel metallic/metal oxide |
Gases purified: | N2 , He, Ne, Kr, Ar, halocarbons, light hydrocarbons |
Outlet purity: |
<1 ppb H2, CO and CO2; <100 ppt H2O, O2 Model 45M: <100 ppb for all contaminants |
Outlet particle filtration: |
0.003 μm Models 45M and 200M: 20 μm |
Maximum differential pressure: | 1379 kPa (200 PSID) |
Minimum operating pressure: | 101 kPa (14.7 PSIA) |
Maximum flow rates: | See datasheet. |
Leak rating: |
1 × 10-9 atm cc/sec. Model 45M: 1 x 10-3 atm-cc/sec |
Maximum inlet challenge of contaminant to maintain product efficiency: | 10 ppm (part-per million) |
Lifetime: | One year at nominal flow rate with 1 ppm inlet challenge of moisture |
Maximum operating temperature: | 65°C (149°F) |