Visitor
Now position:HomePRODUCTSSensing & ControlFlow Controllers
NT® Integrated Flow Controller Model 6500

NT® Integrated Flow Controller Model 6500

Direct flow measurement and closed-loop control provide automated control in bath filling, batch control, blending and chemical spiking.
The DeviceNet™ communication protocol option provides critical diagnostics for alarms, troubleshooting and preventive maintenance.
All PTFE wetted surfaces are safe and dependable for handling a wide range of high purity, aggressive and corrosive chemicals.
Nonmetallic components provide corrosion resistance.
The integral pressure transducer provides additional process information.
Featuring the latest motorized valve and flowmeter technology, encapsulated internal electronics control all aspects of the flow controller.
The compact footprint enables easy field installs where space is limited.
Industry standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility and simplify installation.
100% functionally tested prior to shipment. Performance is calibrated for an accuracy of 1% of full scale.
 
Download : 

 
 
Specifications :

Inlet/Outlet Dimensions
Port Connection A A1 B C
1/4" Flaretek® tube fitting 4.63" (117.6 mm) 4.89" (124.2 mm) 9.61" (244.1 mm) 0.76" (19.3 mm)
3/8" Flaretek® tube fitting 4.63" (117.6 mm) 4.89" (124.2 mm) 9.75" (247.6 mm) 0.76" (19.3 mm)
1/2" Flaretek® tube fitting 4.72" (119.9 mm) 4.89" (124.2 mm) 9.91" (251.7 mm) 0.85" (21.6 mm)
3/4" Flaretek® tube fitting 5.02" (127.5 mm) 5.28" (134.1 mm) 10.15" (257.8 mm) 1.01" (25.7 mm)

Materials of construction:
  Wetted parts: Body: PTFE
Diaphragms: PTFE
Sensor interface: PFA or CTFE
Primary o-ring: Kalrez®
  Nonwetted parts: Polypropylene, PVDF and Viton® (In addition to materials listed above.)
Flow measurement: ±1% of full scale from 20 to 100% of flow range
±2.5% of full scale from 10 to 20% of flow range
[Calibrated using deionized water at 73°F (23°C)]
Repeatability: ±1% of full scale
Reliability: Wetted parts, >3 million cycles
Pressure measurement: 0-60 PSIG (0-413.7 kPa)
Pressure accuracy: ±1% of full scale
Operating pressure: 10 PSIG (68.9 kPa) to 60 PSIG (413.7 kPa)
Output signals: Two 4-20 mA electrically isolated outputs, one for flow and one for pressure or DeviceNet™ communication
Response time: <3 seconds from 10 to 95% of full scale flow range
Over-pressure limit: 100 PSIG (689.5 kPa)
Process temperature: 50°F (10°C) to 149°F (65°C)
Electrical input: 24 VDC (±10%) at 1 amp
Set-point input signal: 4-20 mA, 0-10 VDC, 0-5 VDC or DeviceNet™ communication
Enclosure: NEMA 5/IP54

More information: