NT® Integrated Flow Controller Model 6510
● Ideal for continuous flow control in critical dispense applications, batch control for chemical spiking and blending or on-demand chemical mixing applications.
● Precise flow control at full scale flow ranges as low as 0-15 milliliters per minute.
● Uses proven and reliable differential pressure flow measurement technology and advanced closed-loop process control.
● The small footprint saves valuable space and allows toolmakers to integrate more process functionality.
● All PTFE wetted surfaces are safe and dependable for handling a wide range of high purity, aggressive and corrosive chemicals.
● Hydrofluoric acid compatible sensor option provides many years of service in this harsh chemical.
● Nonmetallic components provide corrosion resistance.
● The integral pressure transducer provides additional process information.
● On-board LED's provide visual indicators for alarming conditions. A discrete two-wire output is also provided.
● The DeviceNet™ communication protocol option provides critical diagnostics for alarms, troubleshooting and preventive maintenance.
● Featuring the latest motorized valve and flowmeter technology, encapsulated internal electronics control all aspects of the flow controller.
● Industry standard Flaretek® flared port connections reduce entrapment area, minimize footprint, provide system design flexibility and simplify installation.
● 100% functionally tested prior to shipment. Performance is calibrated for an accuracy of 1% of full scale.
Specifications :
● Ideal for continuous flow control in critical dispense applications, batch control for chemical spiking and blending or on-demand chemical mixing applications.
● Precise flow control at full scale flow ranges as low as 0-15 milliliters per minute.
● Uses proven and reliable differential pressure flow measurement technology and advanced closed-loop process control.
● The small footprint saves valuable space and allows toolmakers to integrate more process functionality.
● All PTFE wetted surfaces are safe and dependable for handling a wide range of high purity, aggressive and corrosive chemicals.
● Hydrofluoric acid compatible sensor option provides many years of service in this harsh chemical.
● Nonmetallic components provide corrosion resistance.
● The integral pressure transducer provides additional process information.
● On-board LED's provide visual indicators for alarming conditions. A discrete two-wire output is also provided.
● The DeviceNet™ communication protocol option provides critical diagnostics for alarms, troubleshooting and preventive maintenance.
● Featuring the latest motorized valve and flowmeter technology, encapsulated internal electronics control all aspects of the flow controller.
● Industry standard Flaretek® flared port connections reduce entrapment area, minimize footprint, provide system design flexibility and simplify installation.
● 100% functionally tested prior to shipment. Performance is calibrated for an accuracy of 1% of full scale.
Inlet/Outlet | Dimensions | ||
Port Connection | A | B | C |
1/4" Flaretek® tube fitting | 4.64" (117.9 mm) | 0.67" (17.0 mm) | 7.38" (187.5 mm) |
3/8" Flaretek® tube fitting | 4.64" (117.9 mm) | 0.67" (17.0 mm) | 7.52" (191.0 mm) |
1/2" Flaretek® tube fitting | 4.76" (120.9 mm) | 0.67" (17.0 mm) | 7.68" (195.1 mm) |
Materials of construction: | ||
Wetted parts: |
Body, diaphragms: PTFE Sensor interface: PFA or CTFE Primary o-ring: Kalrez® |
|
Nonwetted parts: | PTFE, polypropylene, Viton®, PVDF, Polyurethane, nylon, PVC, FEP | |
Flow measurement: |
±1% of full scale from greater than 20-100% of full scale ±2.5% of full scale from 10 to 20% of full scale Accuracy not specified from 0 –10% of full scale (Calibrated using deionized water at 23°C [73°F]) |
|
Repeatability: |
±0.5% full scale from greater than 20-100% of full scale ±1.0% of full scale from 10-20% of full scale |
|
Pressure measurement: | 0-414 kPa (0-60 PSIG) | |
Pressure accuracy: | ±1% of full scale | |
Operating pressure: | 0 – 414 kPa (0 – 60 PSIG) | |
Output signals: | Two 4-20 mA electrically isolated outputs, one for flow and one for pressure or DeviceNet™ communication | |
Response time: | <3 seconds from 10-95% of full scale flow range | |
Over-pressure limit: | 689.5 kPa (100 PSIG) | |
Process temperature: |
10°-65°C (50°-149°F) for code P1 and P2 10°-35°C (50°-95°F) for code P5 |
|
Electrical input: | 24 VDC (±10%) at 1 amp | |
Setpoint input signal: | 4-20 mA, 0-10 VDC, 0-5 VDC or DeviceNet™ communication | |
Enclosure: | IP64 | |
Weight: | 1.6 kg (3.5 lb) approximate |