NT® Pressure Transducer For DI Water Applications, Flow-through, Model 4230
● Provides reliable pressure measurement in DI water systems while decreasing calibration and maintenance time.
● 100% functionally tested prior to shipment with accuracy of 1% of full scale.
● Provides compatibility and easy integration with electronic displays and monitoring systems.
● No moving parts or fill fluids reduce contamination potential.
● The flow-through design on model 4230 minimizes dead volume, reduces contamination potential.
● Nonmetallic sensing technology provides reliable measurement.
● PTFE, PFA, and Kalrez® wetted surfaces for high-purity applications.
● Compact design enables easy installation.
● Industry standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility and simplify installation.
Specifications :
● Provides reliable pressure measurement in DI water systems while decreasing calibration and maintenance time.
● 100% functionally tested prior to shipment with accuracy of 1% of full scale.
● Provides compatibility and easy integration with electronic displays and monitoring systems.
● No moving parts or fill fluids reduce contamination potential.
● The flow-through design on model 4230 minimizes dead volume, reduces contamination potential.
● Nonmetallic sensing technology provides reliable measurement.
● PTFE, PFA, and Kalrez® wetted surfaces for high-purity applications.
● Compact design enables easy installation.
● Industry standard Flaretek® flared port connections reduce entrapment areas, minimize footprint, provide system design flexibility and simplify installation.
Materials of construction: | |
Wetted parts: | Body: PTFE |
Sensor interface: PFA | |
Primary seal: EPDM | |
Nonwetted parts: | Polypropylene, PVDF and FEP jacketed cable (In addition to materials listed above) |
Pressure range: |
0 to 30 PSIG (0 to 207 kPa), 0 to 60 PSIG (0 to 414 kPa), 0 to 100 PSIG (0 to 690 kPa) |
Over-pressure limit: | 150% of full scale range or maximum pressure rating of fitting |
Process temperature: |
50° to 149°F (10° to 65°C) 149° to 203°F (65° to 95°C) at 75 PSIG (517 kPa) maximum |
Process connection options: | Flaretek®: 1/4", 3/8", 1/2" 3/4", 1" (NPT versions also available) |
Electrical input: | 24 VDC (12-30 VDC input voltage) |
Electrical output: | 4-20 mA, 0-5 VDC, 0-10 VDC |
Electrical cable: | 12´ FEP jacketed cable |
Reference accuracy: | ±1% of full scale (Includes combined effects of linearity, hysteresis and repeatability) |
Enclosure: | NEMA 5/IP54 |