訪客人數
現在位置:首頁產品介紹濾芯PTFE+PFA
QuickChange® AT Cartridge Filters

QuickChange® AT Cartridge Filters

Lowest cost, low flow PTFE filtration for aqueous chemistries for legacy and multi-round housing applications


● Available in retention ratings of 0.05 µm, 0.1 µm and 0.2 µm
● Available in 10", 20", 30" cartridge designs
● 0.9 m² (9.7 ft²) PTFE membrane area - 10", 1.8 m² (19.4 ft²) - 20", 2.7 m² (29 ft²) - 30"
● Utilizing Entegris' standard membrane pleat technology


檔案下載:



規格說明:


Materials:
Membrane: Prewet, nondewetting PTFE
Supports: PFA
Cartridge o-rings: TEV (Teflon® Encapsulated Viton®), Chemraz® or Kalrez®, Viton® Extreme™ EIP
Shell (for disposables): PFA (Chem-Line™ and Chem-Line II type)

 
Retention ratings:
0.03 µm, 0.05 µm, 0.1 µm and 0.2 µm
 
Membrane area:
4" - N/A
10" - 0.9 m2(9.7 ft2)
20" - 1.8 m2 (19.4.4 ft2)
30" - 2.7 m2 (29 ft2)

 
Cartridge connections:
Code 0 (2-222) o-rings
 
Maximum operating conditions:
Maximum forward differential pressure: 0.44 MPa (4.41 bar, 64 PSID) @ 25°C
Maximum forward differential pressure: 0.05 MPa (0.5 bar, 7.3 PSID) @ 150°C
Maximum reverse differential pressure: 0.35 MPa (3.5 bar, 50 PSID) @ 25°C
Maximum operating temperature: 150°C @ 0.05MPa (0.5 bar, 7.3 PSI)

 
Metallic extractables:
Cartridge: Standard - <25 µg/device; UCM - <10 µg/device
Disposable: Standard - <10 µg/device; UCM - < 3 µg/device

 
Particle shedding cleanliness:
<15 particles/10 mL > 0.2 µm at 5 L/min DI water flow
 
TOC recovery (per 10" equivalent):
Cartridges: within 10 ppb of feed after 120 L flush at 1 L/min
Disposables: within 5 ppb of feed after 25 minutes flush at 5 L/min

 
Resistivity recovery:
Resistivity recovery within 0.5 mega-ohm of feed after a 120-liter water flush at 1 l/min (per 10" equivalent)